Kelvin test leads for small devices under test (KK12-4):
- Length: approx. 0.75 m
- Clampable wire diameter: 0 to 10 mm
- Max. measuring current: 30 A
- Avoid use when inductance is < 5 µH (uncertainty will increase)
- Connector: 4 mm
- Part number: KK12-4
Kelvin test leads (KK11-4):
- Length: approx. 1 m
- Clampable wire diameter: approx. 1 to 25 mm
- Max. measuring current: up to 250 A
- Avoid use when inductance is < 10 µH (uncertainty will increase)
- Connector: 4 mm
- Part number: KK11-4
Kelvin test leads for medium-sized devices under test (KK12-6):
- Length: approx. 1.2 m
- Clampable wire diameter: approx. up to 32 mm
- Max. measuring current: up to 1500 A
- Avoid use when inductance is < 30 µH (uncertainty will increase)
- Connector: 6 mm
- Part number: KK12-6
Kelvin test leads for large devices under test (KK11-6):
- Length: approx. 1.4 m
- Clampable wire diameter: approx. up to 35 mm
- Max. measuring current: up to 5000 A
- Avoid use when inductance is < 30 µH (uncertainty will increase)
- Connector: 6 mm
- Part number: KK11-6
Kelvin test leads for 3-Phase Extension Unit (KK31-4):
- Length: approx. 1 m
- Clampable wire diameter: approx. 1 to 25 mm
- Max. measuring current: up to 250 A
- Avoid use when inductance is < 10 µH (uncertainty will increase)
- Connector: 4 mm
- Part number: KK31-4
Kelvin test leads for 3-Phase Extension Unit for medium-sized devices under test (KK32-6):
- Length: approx. 1.2 m
- Clampable wire diameter: approx. up to 32 mm
- Max. measuring current: up to 1000 A RMS
- Avoid use when inductance is < 30 µH (uncertainty will increase)
- Connector: 6 mm
- Part number: KK32-6
Kelvin test leads for 3-Phase Extension Unit for large devices under test (KK31-6):
- Length: approx. 1.4 m
- Clampable wire diameter: approx. up to 35 mm
- Max. measuring current: up to 5000 A
- Avoid use when inductance is < 30 µH (uncertainty will increase)
- Connector: 6 mm
- Part number: KK31-6
Extra long Test Leads
For measuring objects that cannot be placed next to the measurement device due to their size or weight, a set of extra long test leads is available. This cable set also provides the opportunity to connect measuring objects with connecting points spaced far apart.
Use of the extra long cable set is only recommended if they are really necessary, since measuring inaccuracies may increase with very small inductance values.
Test Lead Set length 2m (KL11-4):
- Length: approx. 2 m
- Clampable wire diameter: approx. up to 20 mm
- Max. measuring current: up to 1500 A
- Avoid use when inductance is < 30 µH (uncertainty will increase)
- Connector: 4 mm
- Part number: KL11-4
Test Lead Set length 2m (KL11-6):
- Length: approx. 2 m
- Clampable wire diameter: approx. up to 20 mm
- Max. measuring current: up to 1500 A
- Avoid use when inductance is < 30 µH (uncertainty will increase)
- Connector: 6 mm
- Part number: KL11-6
DPG20 Test Lead Set length 1.8m (KL11-10)
- Length: approx. 1.8 m
- Clampable wire diameter: approx. up to 35 mm
- Max. measuring current: up to 10000 A
- Avoid use when inductance is < 30 µH (uncertainty will increase)
- Connector: 10 mm (DPG20 only)
- Part number: KL11-10